dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Coupler-Refrigerant Line|Page 6512 > < Coupler-Refrigerant Line
Page 2
background image

CAUTION:  Use only the specified O-rings as they are made of a special material for the R-134a system. The use of any other O-rings may allow
the connection to leak.

3. Install new O-rings (8) on the male half of the refrigerant line coupler.
4. Lubricate the O-rings, and the inside of the female half of the refrigerant line coupler (2) with clean R-134a refrigerant oil. Use only refrigerant oil

of the type recommended for the A/C compressor in the vehicle.

5. Position the female half of the coupler over the male half of the coupler.
6. Push together firmly on the two halves of the refrigerant line coupler until the garter spring in the cage on the male half of the coupler snaps over

the flanged end on the female half of the coupler.

7. Make sure that the refrigerant line coupler is fully engaged by firmly pulling the refrigerant lines away from each other on both sides of the

coupler.

8. Install the secondary retaining clip (3) over connected coupler cage (5).
9. Evacuate the refrigerant system.

10. Charge the refrigerant system.

Coupler-Refrigerant Line|Page 6512 > < Coupler-Refrigerant Line