RAM 1500 Truck 4WD V8-4.7L (2008)
1. Position the floor distribution duct (1) onto the bottom of the HVAC housing (2).
2. Install the screws (3) that secure the floor distribution duct to the HVAC housing. Tighten the screws to 1.1 Nm (10 in. lbs.).
3. Install the HVAC housing See: Housing Assembly HVAC/Service and Repair/Removal and Replacement/HVAC Housing - Installation .