dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Diagnostic Trouble Code Descriptions|Page 2511 > < Diagnostic Trouble Code Descriptions|Page 2509
Page 33
background image

VERIFICATION TEST - VER 1.  See: Testing and Inspection/Diagnostic Trouble Code Tests and Associated Procedures/Verification Tests/Body
Verification Test
NO:  Replace all door actuators with a resistance below 30.0 ohms. Perform BODY VERIFICATION TEST - VER 1.  See: Testing and
Inspection/Diagnostic Trouble Code Tests and Associated Procedures/Verification Tests/Body Verification Test

13. RUN THE ACTUATOR CIRCUIT TEST

Reconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
With the DRBIII(R) in HVAC, select System Tests and then select Actuator Circuit Test.
Allow the test to run to completion before proceeding.

Q:  What message does the DRBIII(R) display?

Same message as from start of test

Replace the A/C Heater Control. Perform BODY VERIFICATION TEST - VER 1.  See: Testing and Inspection/Diagnostic Trouble Code
Tests and Associated Procedures/Verification Tests/Body Verification Test

Different message than from start of test

Using the wiring diagram as a guide, inspect the wiring and connectors for conditions causing an intermittent short that set the original test
message. Repair as necessary. If the DRBIII(R) displays a message for a different door driver circuit, return to Test 1 of this diagnostic
procedure. Perform BODY VERIFICATION TEST - VER 1.  See: Testing and Inspection/Diagnostic Trouble Code Tests and Associated
Procedures/Verification Tests/Body Verification Test

Blend/Mode/Recirc Door Operation Improper - Dual-Zone

BLEND/MODE/RECIRC DOOR OPERATION IMPROPER (DUAL-ZONE)

Diagnostic Trouble Code Descriptions|Page 2511 > < Diagnostic Trouble Code Descriptions|Page 2509