dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Leak Detection Pump|Page 3283 > < Leak Detection Pump
Page 2
background image

The LDP (4) and LDP filter are attached to the front of the EVAP canister mounting bracket. The LDP and LDP filter are replaced (serviced) as one
unit.

1. Install LDP to mounting bracket. Refer to Torque Specifications.
2. Install LDP filter to mounting bracket. Refer to Torque Specifications.
3. Carefully install vapor/vacuum lines to LDP, and install hose to LDP filter. The vapor/vacuum lines and hoses must be firmly connected. Check

the vapor/vacuum lines at the LDP, LDP filter and EVAP canister purge solenoid for damage or leaks. If a leak is present, a Diagnostic Trouble
Code (DTC) may be set.

4. Connect electrical connector to LDP.
5. If necessary, install skid plate(s).

Leak Detection Pump|Page 3283 > < Leak Detection Pump