21.

Install the B-Pillar plug.

22.

Adjust the stabilizer pin so that pin fits snug into the front striker latch grommet with the door closed. A small amount of grease can be applied to
the end of the stabilizer pin to help identify when the pin contacts the grommet. Adjust the pin out until witness marks appear on the front striker
grommet then, tighten the lock nut on the pin.

23.

Apply a thin coat of weatherstrip lubricant (p/n 04773427) to the sliding door weatherstrip.

24.

Open and close the sliding door to verify the repair.

25.

If the door is still difficult to close, adjust the sliding door closed-position locking catch/striker. Refer to the 1997 Ram Van/Wagon Service
Manual (Publication No. 81-370-7107), page 23-70, for information regarding adjustment of the sliding door closed-position locking catch/striker.

Sliding Door - Difficult To Close|Page 4434 > < Sliding Door - Difficult To Close|Page 4432