Hazard Warning Flasher: Description and Operation
Hazard Flasher

Circuit A3 from the battery positive post supplies power circuit A15. Circuit A15 supplies battery voltage to fuse 3 in the fuse block. Circuit A15 has an
in-line fusible link.

Circuit L9 from fuse 3 supplies battery voltage to the hazard warning flasher. Circuit L19 from the flasher connects to the turn signal/hazard switch
circuitry in the multi-function switch.

When the operator depresses the hazard flasher button, the multi-function switch connects circuit L19 to circuits L60, L61, L62, and L63. Circuit L62
powers the right rear turn signal/stop lamp. Circuit L63 powers the left rear turn signal/stop lamp. Circuit L6O powers the right turn signal lamp. Circuit
L61 powers the left turn signal lamp.

Circuit L6O also splices to feed the instrument cluster right turn signal indicator lamp. Circuit L61 splices to feed the instrument cluster left turn signal
indicator lamp.