SYMPTOM

* ONE GAUGE NOT OPERATING PROPERLY

POSSIBLE CAUSES

-

Speedometer related DTC's present

-

Oil gauge not reading > 4 psi at idle

-

Pinion factor incorrect

-

Oil level low

-

Charging related DTC's present

-

Instrument cluster circuit board defective

-

Oil pressure sensor defective

-

Instrument cluster defective

-

Oil pressure sense circuit open

-

Oil pressure sense signal circuit short to ground

-

Cooling system operation faulty

-

DRB not showing PCM active ON bus

-

DRB shows ECT sensor voltage too high

-

DRB shows ECT sensor voltage too low

-

Fuel gauge defective

-

Oil pressure switch defective

-

Powertrain Control Module (JTEC) defective

Courtesy Lamps Inop From All Doors & Courtesy Lamp Switch

SYMPTOM

* COURTESY LAMPS INOPERATIVE FROM ALL DOORS & COURTESY LAMP SWITCH

POSSIBLE CAUSES

-

No response (CTM) / CCD bus failure

-

Courtesy lamp switch output circuit open

-

Fused B (+) circuit open

-

Headlamp switch defective - courtesy lamp defeat switch

-

Courtesy lamp driver circuit open

Courtesy Lamps Inoperative From Both Front Doors

SYMPTOM

* COURTESY LAMPS INOPERATIVE FROM BOTH FRONT DOORS

POSSIBLE CAUSES

-

CTM defective - courtesy lamp driver

-

Courtesy lamp driver circuit open to splice

Courtesy Lamps Inoperative From Courtesy Lamp Switch

SYMPTOM

* COURTESY LAMPS INOPERATIVE FROM COURTESY LAMP SWITCH

POSSIBLE CAUSES

-

Headlamp switch ground circuit open

-

Headlamp switch defective - Courtesy lamp driver

-

Courtesy lamp driver open headlamp switch to splice

Courtesy Lamps Inoperative From Either Auxiliary Door

SYMPTOM

* COURTESY LAMPS INOPERATIVE FROM EITHER AUXILIARY DOOR

POSSIBLE CAUSES

-

Auxiliary door switch defective - open 

-

Courtesy lamp driver circuit open - Auxiliary door switch

 

Courtesy Lamps On at All Times

SYMPTOM

* COURTESY LAMPS ON AT ALL TIMES

POSSIBLE CAUSES

-

No response (CTM) / CCD bus failure

-

Auxiliary door switch defective - dhorted

-

CTM defective - Courtesy lamp driver function shorted