dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Compressor HVAC > < Front Blower Motor Switch Test|Page 4990
Page 1
background image

Blower Motor Switch: Service and Repair

REAR BLOWER MOTOR SWITCH

The rear blower motor switch is used only on models with the optional rear heater-A/C unit.

REMOVAL

1. Disconnect and isolate the battery negative cable.

2. Remove the accessory switch plate from the instrument panel. Refer to Accessory Switch Plate Removal and Installation.

See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Instrument Panel Accessory Switch Plate

Rear Blower Motor Switch Remove/Install

3. Rotate the illumination lamp socket counterclockwise to disengage it from the back of the switch housing.

4. Pull the knob off of the blower motor switch stem from the front of the accessory switch plate.

5. With a small thin-bladed screwdriver, gently pry the sides of the accessory switch plate to release the two snap clips on each side of the rear

blower motor switch housing.

6. Remove the rear blower motor switch from the back of the accessory switch plate.

INSTALLATION

1. Position the rear blower motor switch on the back of the accessory switch plate.

2. Firmly and evenly press the rear blower motor switch into the back of the accessory switch plate until it snaps into place. Be certain that all of the

switch snap clip retainers are fully engaged.

3. Reinstall the knob onto the rear blower motor switch stem from the front of the accessory switch plate. Be certain to index the flat on the switch

stem with the flat in the hub of the knob.

4. Reinstall the illumination lamp socket to the back of the rear blower motor switch housing.

5. Reinstall the accessory switch plate in the instrument panel. Refer to Accessory Switch Plate Removal and Installation.

See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Instrument Panel Accessory Switch Plate

6. Connect the battery negative cable.

Compressor HVAC > < Front Blower Motor Switch Test|Page 4990