Blower Motor Switch: Testing and Inspection
Front Blower Motor Switch Test

FRONT BLOWER MOTOR SWITCH

WARNING:  ON VEHICLES EQUIPPED WITH AIRBAGS, REFER TO AIR BAGS AND SEAT BELTS/AIR BAGS BEFORE
ATTEMPTING ANY STEERING WHEEL, STEERING COLUMN, OR INSTRUMENT PANEL COMPONENT DIAGNOSIS OR
SERVICE. FAILURE TO TAKE THE PROPER PRECAUTIONS COULD RESULT IN ACCIDENTAL AIRBAG DEPLOYMENT
AND POSSIBLE PERSONAL INJURY
.

Front

1. Turn the ignition switch to the OFF position. Disconnect and isolate the battery negative cable. Remove the heater-A/C control from the

instrument panel. See Heater-A/C Control Removal and Installation.
See: Heating and Air Conditioning/Control Assembly/Service and Repair
Check for continuity between the ground circuit (Z1V) cavity of the heater-A/C mode control wire harness connector and a good ground. There
should be continuity. If OK, go to Step 2. If not OK, repair the open circuit to ground as required.

2. With the heater-A/C control wire harness connector unplugged, place the heater-A/C mode control switch knob in any position except the Off

position. Check for continuity between the two ground circuit terminals in the mode switch receptacle of the heater-A/C control. There should be
continuity. If OK, go to Step 3. If not OK, replace the faulty heater-A/C control unit.

3. Check for continuity between the ground circuit (C 72) cavities of the heater-A/C mode control wire harness connector and the heater-A/C blower

speed switch wire harness connector. There should be continuity. If OK, go to Step 4. If not OK, repair the open circuit as required.

4. Check for continuity between the ground circuit (C 72) terminal and each of the blower motor driver circuit terminals in the blower speed switch

receptacle of the heater-A/C control as you move the blower motor switch knob to each of the four speed positions. There should be continuity at
each driver circuit terminal in only one blower motor switch speed position. If OK, test and repair the blower driver circuits between the
heater-A/C control blower speed switch wire harness connector and the front blower motor resistor or the front high speed blower motor relay as
required. If not OK, replace the faulty heater-A/C control unit.

Front Blower Motor Switch Test|Page 467 > < Blower Motor Switch|Service Precautions|Page 464