dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Blower Motor Relay Replacement|Page 4765 > < Blower Motor Relay|Page 4762
Page 1
background image

Blower Motor Relay: Service and Repair
Blower Motor Relay Replacement

BLOWER MOTOR RELAY

FRONT

1. Disconnect and isolate the battery negative cable.

Power Distribution Center

2. Remove the cover from the Power Distribution Center (PDC).

3. Refer to the label on the PDC for blower motor relay identification and location.

4. Unplug the blower motor relay from the PDC.

5. Install the blower motor relay by aligning the relay terminals with the cavities in the PDC and pushing the relay firmly into place.

6. Install the PDC cover.

7. Connect the battery negative cable.

8. Test the relay operation.

REAR

Rear Blower Motor Relay Remove/Install

The rear blower motor relay is used only on models with the optional rear heater-A/C unit.

1. Disconnect and isolate the battery negative cable.

2. Remove the cover from the rear heater-A/C unit.

Blower Motor Relay Replacement|Page 4765 > < Blower Motor Relay|Page 4762