dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Air Door Cable, HVAC > < Air Door Actuator / Motor, HVAC|Service and Repair
Page 2
background image

5. Remove the two screws that secure the panel-defrost door actuator to the heater-A/C housing.
6. Remove the panel-defrost door actuator from the heater-A/C housing.
7. Reverse the removal procedures to install. Tighten the panel-defrost door actuator mounting screws to 2.2 N.m (20 in. lbs.).

Recirculation Air Door Actuator
1. Disconnect and isolate the battery negative cable.
2. Remove the glove box from the instrument panel.

Recirculation Air Door Actuator

3. Reach through the glove box opening to access and unplug the vacuum harness connector from the recirculation air door actuator.
4. Loosen the two nuts on the studs that secure the recirculation air door actuator to the mounting bracket on the heater-A/C housing.
5. Slide the two actuator mounting studs out of the slots in the actuator mounting bracket.
6. Pull the recirculation actuator downward far enough to access the clip that retains the actuator link to the recirculation air door lever.
7. Unsnap the clip from the recirculation actuator link and disengage the link from the recirculation air door lever.
8. Remove the recirculation actuator from the heater-A/C housing.
9. When reinstalling the recirculation actuator, insert a screwdriver or another suitable tool through the recirculation air intake grille to prop the

recirculation air door up in the open position far enough to access the recirculation air door lever through the instrument panel glove box opening.

10. Reverse the remaining removal procedures to install. Tighten the mounting nuts until the recirculation air door actuator is seated to the mounting

bracket on the heater-A/C housing.

Air Door Cable, HVAC > < Air Door Actuator / Motor, HVAC|Service and Repair