dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Expansion Block/Orifice Tube|Locations|Page 5358 > < Expansion Block/Orifice Tube|Locations
Page 1
background image

Expansion Block/Orifice Tube: Description and Operation

A/C ORIFICE TUBE

The fixed orifice tube is installed in the liquid line between the outlet of the condenser and the inlet of the evaporator. The fixed orifice tube is only
serviced as an integral part of the liquid line.

Fig. 12 Fixed Orifice Tube - Typical

The inlet end of the fixed orifice tube has a nylon mesh filter screen, which filters the refrigerant and helps to reduce the potential for blockage of the
metering orifice by refrigerant system contaminants. The outlet end of the tube has a nylon mesh diffuser screen. The O-rings on the plastic body of the
fixed orifice tube seal the tube to the inside of the liquid line and prevent the refrigerant from bypassing the fixed metering orifice.

The fixed orifice tube is used to meter the flow of liquid refrigerant into the evaporator coil. The high-pressure liquid refrigerant from the condenser
expands into a low-pressure liquid as it passes through the metering orifice and diffuser screen of the fixed orifice tube.

The fixed orifice tube cannot be repaired and, if faulty or plugged, the liquid line assembly must be replaced.

Expansion Block/Orifice Tube|Locations|Page 5358 > < Expansion Block/Orifice Tube|Locations