Page 1
background image

Washer Fluid Level Indicator: Testing and Inspection

The diagnosis found here addresses an inoperative washer fluid indicator condition. If the problem being diagnosed is related to indicator accuracy, be
certain to confirm that the problem is with the indicator or washer fluid level switch input and not with a damaged or empty washer fluid reservoir, or
inoperative instrument cluster indicator control circuitry. Inspect the washer fluid reservoir for proper fluid level and signs of damage or distortion that
could affect washer fluid level switch performance and perform the instrument cluster actuator test before you proceed with the following diagnosis. If
no washer fluid reservoir or instrument cluster control circuitry problem is found, the following procedure will help to locate a short or open in the
washer fluid switch sense circuit. Refer to the appropriate wiring information. The wiring information includes wiring diagrams, proper wire and
connector repair procedures, details of wire harness routing and retention, connector pin-out information and location views for the various wire harness
connectors, splices and grounds.

WARNING:  ON VEHICLES EQUIPPED WITH AIRBAGS, DISABLE THE AIRBAG SYSTEM BEFORE ATTEMPTING ANY STEERING
WHEEL, STEERING COLUMN, OR INSTRUMENT PANEL COMPONENT DIAGNOSIS OR SERVICE. DISCONNECT AND ISOLATE
THE BATTERY NEGATIVE (GROUND) CABLE, THEN WAIT TWO MINUTES FOR THE AIRBAG SYSTEM CAPACITOR TO
DISCHARGE BEFORE PERFORMING FURTHER DIAGNOSIS OR SERVICE. THIS IS THE ONLY SURE WAY TO DISABLE THE
AIRBAG SYSTEM. FAILURE TO TAKE THE PROPER PRECAUTIONS COULD RESULT IN ACCIDENTAL AIRBAG DEPLOYMENT
AND POSSIBLE PERSONAL INJURY.

Indicator Does Not Illuminate With Washer Reservoir Empty

1. Disconnect and isolate the battery negative cable. Disconnect the headlamp and dash wire harness connector for the washer fluid level switch from

the washer fluid level switch connector receptacle. Check for continuity between the ground circuit cavity of the headlamp and dash wire harness
connector for the washer fluid level switch and a good ground. There should be continuity. If OK, go to Step 2. If not OK, repair the open ground
circuit to ground (G100) as required.

2. Remove the instrument cluster from the instrument panel. Check for continuity between the washer fluid switch sense circuit cavities of the

headlamp and dash wire harness connector for the washer fluid level switch and the instrument panel wire harness connector (Connector C2) for
the instrument cluster. If OK, replace the faulty washer fluid level switch. If not OK, repair the open washer fluid switch sense circuit between the
washer fluid level switch and the instrument cluster as required.

Indicator Stays Illuminated With Washer Reservoir Full
1. Disconnect and isolate the battery negative cable. Disconnect the headlamp and dash wire harness connector for the washer fluid level switch from

the washer fluid level switch connector receptacle. Check for continuity between the ground circuit terminal and the washer fluid switch sense
terminal in the washer fluid level switch connector receptacle. There should be no continuity If OK, go to Step 2. If not OK, replace the faulty
washer fluid level switch.

2. Remove the instrument cluster from the instrument panel. Check for continuity between the washer fluid switch sense circuit cavity of the

headlamp and dash wire harness connector for the washer fluid level switch and a good ground. There should be no continuity. If not OK, repair
the shorted washer fluid switch sense circuit between the washer fluid level switch and the instrument cluster as required.