2. Install the two screws (2) that secure the recirculation door actuator (3) to the air inlet housing (1). Tighten the screws to 1.1 Nm (10 in. lbs.).
3. Install the air inlet housing See: Housing Assembly HVAC/Service and Repair/Removal and Replacement/HVAC Housing - Installation.
4. Install the HVAC housing assembly See: Housing Assembly HVAC/Service and Repair/Removal and Replacement/HVAC Housing - Installation.
5. Initiate the Actuator Calibration function using a scan tool See: Testing and Inspection/Component Tests and General Diagnostics/HVAC System
Test.