Alternator: Service and Repair
Generator Cartridge Fuse Replacement

If a generator cartridge fuse fails, be certain to inspect and test the vehicle charging system before replacing the cartridge fuse and returning the vehicle
to service. Refer to Charging System for the charging system diagnostic procedures.

REMOVAL

1. Disconnect and isolate the battery negative cable.
2. Unlatch and remove the cover from the Power Distribution Center (PDC).
3. Remove the two screws that secure the generator cartridge fuse to the two B(+) terminal stud bus bars within the PDC.
4. Remove the generator cartridge fuse from the PDC.

INSTALLATION

1. Position the generator cartridge fuse onto the two B(+) terminal stud bus bars within the PDC.
2. Install and tighten the two screws that secure the generator cartridge fuse to the two B(+) terminal stud bus bars within the PDC. Tighten the

screws to 3.4 Nm (30 in. lbs.). Be certain that both screws are tightened to the proper torque value.

3. Install and latch the cover onto the PDC.
4. Reconnect the battery negative cable.

Voltage Regulator > < Generator Replacement|Page 5451