Do not exceed the limits shown in the table below:

-

Voltage between any terminal and ground must not exceed 500v DC or 500v peak AC.

-

Use caution when measuring voltage above 25v DC or 25v AC.

-

Use the low current shunt to measure circuits up to 10A. Use the high current clamp to measure circuits exceeding 10A.

-

When testing for the presence of voltage or current, make sure the meter is functioning correctly. Take a reading of a known voltage or current
before accepting a zero reading.

-

When measuring current, connect the meter in series with the load.

-

Disconnect the live test lead before disconnecting the common test lead.

-

When using the meter function, keep the DRBIII(R) away from spark plug or coil wires to avoid measuring error from outside interference.