Valve Cover: Removal and Replacement

Rocker Housing

ROCKER HOUSING

1. Remove the breather cover and the cylinder head cover. 
2. Remove injector harness nuts from injectors.
3. Remove cylinder head cover gasket. 
4. Remove rocker housing bolts.
5. Remove rocker housing and gasket.

Cylinder Head Cover

CYLINDER HEAD COVER

1. Disconnect both negative battery cables.
2. Remove the Breather Cover Capscrews (8-M6 screws).
3. Remove the CCV breather and filter cover (3).
4. Disconnect CCV Tube (4) at the CDR valve (one spring clamp) and remove 10mm nut from tube bracket at EGR Cooler support bracket stud.
5. Disconnect CDR valve Tube to Air Inlet Silencer (Spring Clamp).
6. Disconnect CDR/Valve cover pressure sensor connector.
7. Remove Oil fill cap.
8. Remove CCV oil drains (2) from valve cover (2 hoses).
9. Disconnect both injector harness connectors (1).

10. Remove six (6) valve cover capscrews (10mm).
11. Remove the valve cover.
12. Loosen injector wire nuts from the valve cover gasket (8mm).
13. Remove gasket.

Cylinder Head Cover Gasket

CYLINDER HEAD COVER GASKET

Procedures|Page 2923 > < Procedures