Crankcase Filter: Service and Repair
Installation

FILTER ELEMENT INSPECTION

1. Inspect the crankcase breather assembly by ensuring the oil drain hoses are not kinked or cracked.
2. Inspect all external hose connections for signs of leakage, repair where necessary. Inspect the breather for cracks or damage.
3. Inspect the filter element sealing surface for gouges or cracks; this surface should be smooth and free of abrasions.

FILTER ELEMENT INSTALLATION

1. Clean the filter sealing surface on the cylinder head cover with a clean shop towel.
2. Install the new filter element, lubrication of the new sealing surface is not recommended.
3. Press the new filter into the cylinder head cover cavity until fully seated.
4. Install the breather cover assembly.

BREATHER COVER INSTALLATION

1. Inspect the filter element for proper installation. The filter should be completely seated around the circumference of the sealing surface.
2. Install the breather cover to the cylinder head cover.
3. Install the capscrews surrounding the breather cover.
4. Install the breather drain hoses onto the hose barbs. Do not damage or hose connection during installation.