Accumulator HVAC: Service and Repair

Fig 28  Low Pressure Cycling Clutch Switch

WARNING: Review the Service Precautions before leak testing the system.

REMOVAL

1. Disconnect and isolate the battery negative cable.
2. Recover the refrigerant from the refrigerant system.
3. Disconnect the refrigerant line couplers from the accumulation. Install plugs in, or tape over all of the open refrigerant fittings.
4. Unplug the wire harness connector from the low pressure cycling clutch switch.

Fig 29  Accumulator Removal/Installation

5. Loosen the screw that secures the accumulator band to the support bracket.
6. Remove the accumulator.

INSTALLATION

1. Install the accumulator band screw in the support bracket.
2. Tighten the band screw in the support bracket.
3. Plug the wire harness connector into the low pressure cycling clutch switch.
4. Remove the plugs or tape from the refrigerant line fittings. Connect the refrigerant lines to the accumulator.
5. Evacuate and charge the refrigerant system.
6. Connect the battery negative cable.

NOTE:  If the accumulator is replaced, add 120 ml (4 oz.) of refrigerant oil to the refrigerant system.