Dodge Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Description and Operation|Page 6205
Page 2
background image

bolts (8) at this time.

2. Remove the tape or plugs from the opened refrigerant system connections.
3. Lubricate new rubber O-ring seals with clean refrigerant oil and install them onto the accumulator tube fittings (1 and 6). Use only the specified

O-rings as they are made of a special material for the R-134a system. Use only refrigerant oil of the type recommended for the A/C compressor in
the vehicle.

4. Connect the spring-lock coupler that secures the accumulator inlet tube (3) to the evaporator outlet tube (5) and install the secondary retaining clip

(4).

5. Tighten the accumulator bracket bolts to 4.5 N.m (40 in.lbs.).
6. Connect the A/C suction line (10) to the accumulator outlet tube (2) and install the secondary retaining clip (11).
7. Install the air filter housing cover.
8. Evacuate the refrigerant system.
9. Charge the refrigerant system.

10. Reconnect the battery negative cable.