dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

EGR Valve > < Component Locations|Page 3356
Page 3
background image

3. Clean EGR tube where it joins EGR valve.
4. Position new gasket between EGR tube flange and EGR valve assembly.
5. Install two bolts (3) connecting EGR tube (4) to valve assembly (2). Tighten bolts. Refer to Torque Specifications.
6. Connect electrical connector (1) to EGR solenoid (2).

EGR Valve > < Component Locations|Page 3356