dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Airbag System|Page 2847 > < Airbag System|Page 2845
Page 1
background image

Central Timer Module: Description and Operation
Bus Failure Message

Bus Failure Messages
Short to Battery
 - Either or both of the bus wires are shorted to the battery potential.

Short to 5 Volts - Either or both of the bus wires are shorted to a 5-volt potential.

Short to Ground - Either or both of the bus wires are shorted to ground.

Bus (+)- & Bus (-) Shorted Together - The two bus wires are shorted together.

No Termination - The bus system has lost connection with all of its terminators. The Instrument Cluster (MIC) and Powertrain Controller (PCM) supply
termination for the 1998 Ram Trucks.

Bus Bias Level Too Low - Either of both of the bus wire potentials are significantly below their normal 2.5 volts.

Bus Bias Level Too High - Either of both of the bus wire potentials are significantly above their normal 2.5 volts.

No Bus Bias - The bus system has lost connection with all modules that provide bias. The Instrument Cluster (MIC) provides the CCD bus bias for the
1998 Ram Trucks.

Bus (+) Open - The bus (+) wire has lost connection with termination and/or bias.

Bus (-) Open - The bus (-) wire has lost connection with termination and/or bias.

Not receiving Bus Messages Correctly - The DRB cannot communicate over the bus and does not know why.

Airbag System|Page 2847 > < Airbag System|Page 2845