dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Blend Door Actuator Replacement|Page 5131 > < Blend Door Actuator Replacement
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Mode Door Actuator Replacement

WARNING:  ON VEHICLES EQUIPPED WITH AIR-BAGS, FAILURE TO TAKE THE PROPER PRECAUTIONS COULD RESULT IN
ACCIDENTAL AIR-BAG DEPLOYMENT AND POSSIBLE PERSONAL INJURY
.

REMOVAL

Recirculation Air Door Actuator

WARNING:  REVIEW THE WARNINGS AND CAUTIONS BEFORE PERFORMING THE FOLLOWING OPERATION.

1. Disconnect and isolate the battery negative cable.
2. if the vehicle is not equipped with air conditioning, go to Step 5. if the vehicle is equipped with air conditioning, disconnect the suction line

jumper at the expansion valve.

3. Remove the screws that secure the filter-drier and its mounting bracket to the heater-A/C housing and the cowl side panel. Swing the filter-drier,

mounting bracket and refrigerant plumbing as a unit out of the way towards the center of the vehicle.

Recirculation Air Door Actuator Remove/Install

4. Unplug the vacuum harness connector from the recirculation air door actuator located on the top of the recirculation housing near the cowl side

panel in the engine compartment.

5. Unsnap the retaining clip that secures the recirculation air door actuator link to the recirculation air door lever.
6. Loosen the two nuts that secure the recirculation air door actuator to the bracket molded into the upper forward edge of the recirculation housing.
7. Disengage the actuator link from the recirculation air door lever.
8. Lift the recirculation air door actuator upwards far enough to disengage the two mounting studs from the slotted holes in the molded bracket on the

upper forward edge of the recirculation housing.

9. Remove the recirculation air door actuator from the engine compartment.

10. Reverse the removal procedures to install. Tighten the mounting nuts to 2.2 N.m (20 in. lbs.).

Floor-defrost Door Actuator
1. Disconnect and isolate the battery negative cable.
2. Remove the instrument panel assembly from the vehicle.  Refer to:  "Instrument Panel Gauges and Warning Indicators : Instrument Panel :

Service and Repair"  See: Instrument Panel, Gauges and Warning Indicators/Instrument Cluster / Carrier/Service and Repair

Floor-Defrost Door Actuator

3. Unplug the two vacuum harness connectors from the floor-defrost door actuator located on a mount between the two defroster outlets on the left

Blend Door Actuator Replacement|Page 5131 > < Blend Door Actuator Replacement