dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Remote Keyless Entry - Intermittently Inoperative|Page 6608 > < Remote Keyless Entry - Intermittently Inoperative|Page 6606
Page 4
background image

2.

Inspect the power door lock actuator contact wiring access opening in the hinge reinforcement bracket for possible contact between the terminals
of the actuator contacts to the hinge reinforcement bracket (Figure 1). There should be at least 6.35 mm (0.25 in.) clearance between the terminals
and the hinge reinforcement bracket.

3.

If there is less than 6.35 mm (0.25 in.) clearance between the terminals and hinge reinforcement, perform the Repair Procedure. If the clearance is
6.35 mm (0.25 in.) or greater, the power door lock/RKE system will require further diagnosis. Use the procedures described in the 1997 Ram
Van/Wagon Service Manual (Publication No. 81-370-7107), pages 8P-2 through 8P-4 for diagnostic procedures regarding the power door
lock/RKE system.

PARTS REQUIRED:

1

J8993799

Rustproofing And Sealant

REPAIR PROCEDURE:

This bulletin involves enlarging the opening in the hinge reinforcement bracket for the wiring access to the power door lock actuator contacts.

1.

Disconnect the battery negative cable.

2.

Disconnect the power door lock actuator contacts from the wiring harness noting the wire orientation to the contact for proper re-assembly.

Remote Keyless Entry - Intermittently Inoperative|Page 6608 > < Remote Keyless Entry - Intermittently Inoperative|Page 6606