10. Remove the two screws (1) that secure the panel/floor door outlet (2) to the top of the HVAC housing (4).

NOTE: If the foam seal on the panel/floor door outlet is deformed or damaged, it must be replaced.

11. Release the two retaining tabs (3) that secure the panel/floor door outlet to the front of the HVAC housing and remove the door outlet.

12. Remove the three screws (1) that secure the panel/floor door assembly (2) to the top of the HVAC housing (3) and remove the door assembly.

13. To remove the panel/floor-air doors (1) from the panel/floor door plate (2), first carefully release the retaining tabs of actuator coupler (3) located

on the inside surface of the door plate and pull the actuator coupler out of the pivot shaft of the panel/floor-air doors.

NOTE: If the seals on the air doors is deformed or damaged, the air doors must be replaced.

14. Remove the panel/floor-air doors from the panel/floor door plate.