Condenser HVAC: Service and Repair
Installation

5.9L/6.7L DIESEL ENGINES

CAUTION:  Be certain to adjust the refrigerant oil level when servicing the A/C refrigerant system. Failure to properly adjust the refrigerant
oil level will prevent the A/C system from operating as designed and can cause serious A/C compressor damage.

NOTE:  When replacing multiple A/C system components, refer to the Refrigerant Oil Capacities chart to determine how much oil should be added to
the refrigerant system.

NOTE:  If only the A/C condenser is being replaced, add 30 milliliters (1 fluid ounce) of refrigerant oil to the refrigerant system. Use only refrigerant
oil of the type recommended for the A/C compressor in the vehicle.

NOTE:  Replacement of the refrigerant line O-ring seals and gaskets is required anytime a refrigerant line is opened. Failure to replace the rubber O-ring
seals and metal gaskets could result in a refrigerant system leak.

NOTE:  Illustration shown with air seal removed for clarity.

1. Position the A/C condenser (5) into the engine compartment.

2. Install the four bolts (2, 4, 6 and 7) that secure the A/C condenser to the charge air cooler. Tighten the bolts to 10.5 Nm (95 in. lbs.).

3. Remove the tape or plugs from the discharge and liquid line fittings and condenser ports.

4. Lubricate new rubber O-ring seals with clean refrigerant oil and install them and new gaskets onto the refrigerant line fittings. Use only the

specified O-rings as they are made of a special material for the R-134a system. Use only refrigerant oil of the type recommended for the A/C
compressor in the vehicle.

5. Connect the A/C discharge line (1) and the A/C liquid line (3) onto the A/C condenser.

NOTE:  Be certain that each of the radiator and condenser air seals are installed in their proper locations. These air seals are required for the A/C
and engine cooling systems to perform as designed.

6. Position the air seal over the right end of the A/C condenser and install the air seal retainers.

7. Reconnect the negative battery cable.

8. Evacuate the refrigerant system.

9. If the A/C condenser is being replaced, add 30 milliliters (1 fluid ounce) of refrigerant oil to the refrigerant system. When replacing multiple A/C

system components, refer to the Refrigerant Oil Capacities chart to determine how much oil should be added to the refrigerant system. Use only