RAM 3500 Truck 4WD L6-6.7L DSL Turbo VIN A (2007)
Fuel Inlet Metering Valve: Service and Repair
Removal
REMOVAL
1. Remove electrical connector (6) from Fuel Control Actuator (FCA).
2. Remove FCA mounting screws (1).
3. Twist and pull FCA to remove from injection pump.