background image

5. Disconnect the right side instrument panel duct adapter (2) from the right side instrument panel duct (1) and remove the adapter.
6. Remove the screw that secures each intermediate demister duct (3 and 4) to the instrument panel cover.
7. Disconnect the intermediate demister ducts from the demister ducts and remove the intermediate ducts.
8. Disconnect the left side instrument panel duct adapter (6) from the right side instrument panel duct (5) and remove the adapter
9. Remove the instrument panel cover See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Instrument

Panel Cover - Removal.

10. Remove the two screws that secure each demister duct to the instrument panel cover and remove the ducts.

Instrument Panel Demister Duct - Installation

INSTALLATION

1. Position the demister ducts onto the instrument panel cover.
2. Install the two screws that secure each demister duct to the instrument panel cover. Tighten the screws to 2.2 Nm (20 in. lbs.).
3. Install the instrument panel cover See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Instrument

Panel Cover - Installation.

4. Position the left side instrument panel duct adapter (6) into the instrument panel and connect it to the left panel duct.
5. Position the intermediate demister ducts (3 and 4) into the instrument panel and connect them to the demister ducts.
6. Install the screw that secures each intermediate demister duct to the instrument panel cover. Tighten the screws to 2.2 Nm (20 in. lbs.).
7. Position the right side instrument panel duct adapter (2) into the instrument panel and connect it to the right panel duct.

Defroster Duct - Removal|Page 4209 > < Defroster Duct - Removal|Page 4207