WARNING: Locking constant tension hose clamps are used on the EGR cooler system hoses. When removing, use only tools designed for
servicing this type of clamp. Always wear safety glasses when servicing locking constant tension clamps.

1. Remove engine cover (1).
2. Drain cooling system below level of EGR cooler  See: Engine, Cooling and Exhaust/Cooling System/Service and Repair .

3. Remove EGR heat shield.

4. Disconnect EGR temperature sensor electrical connector (4).
5. Loosen EGR valve mounting bolts. Do not remove.
6. Remove EGR crossover tube clamp (5).
7. Remove EGR crossover tube clamp (3).
8. Remove EGR crossover tube clamp (1 and 3).