RAM 3500 HD Truck 2WD L6-6.7L DSL Turbo (2008)
Fuel Inlet Metering Valve: Service and Repair
Installation
INSTALLATION
1. Lubricate new Fuel Control Actuator (FCA) O-ring with clean oil before installation.
2. Turn FCA in a clockwise direction while pressing it into machined bore on rear of fuel injection pump. Be sure FCA flange is flush with the
mounting surface on fuel injection pump.
3. Install FCA mounting screws (1) by hand.
4. Tighten FCA mounting screws (1) to 7 Nm (62 in. lbs).