dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Computers/Controls - CCN Update For Recall J35|Page 3584 > < Computers/Controls - CCN Update For Recall J35|Page 3582
Page 4
background image

e. Select "Download to Client".

f.

Select "Close" after the download is complete, then select the "Back arrow.

g. Highlight the listed calibration.

h. Select "Update Controller" and follow the on screen instructions.

i.

When the update is completed, select "OK".

7. Disconnect the StarMOBILE vehicle cable from the vehicle.

8. Turn off the StarMOBILE scan tool and then restart the scan tool.

NOTE:

The StarMOBILE scan tool must be shut down and restarted to unlock the flash.

9. Retrieve the CCN part number. With the StarMOBILE on the "Home" screen, follow the procedure below:

a. Select "ECU View".

b. Select "CCN" in the list of modules.

c. Select "More Options".

d. Select "ECU Flash".

e. Verify the "Part Number" (displayed at the end of the "Resident flash file for" statement) has been updated to the new part number. If it has

updated, then the flash has been completed successfully.

10. Clear any Diagnostic Trouble Codes (DTCs).

CCN MODULE REPROGRAM - USING StarSCAN(R):

1. Connect the CH941 0 StarSCAN(R) ethernet cable to the StarSCAN(R) and the dealer's network drop.

2. Connect the CH9404D StarSCAN(R) vehicle cable to the StarSCAN(R) and the vehicle.

3. Turn the ignition switch to the "RUN/ON" position.

4. Power ON the StarSCAN(R).

5. Retrieve the old CCN module part number and reprogram the CCN module. Using the StarSCAN(R) at the "Home" screen:

a. Select "ECU View"

b. Touch the screen to highlight the CCN in the list of modules.

c. Select "More Options"

d. Select "ECU Flash".

e. Record the part number at the top of the "Flash CCN" screen on the WRO for later reference.

f.

Select "Browse for New File". Follow the on screen instructions.

g. Select "Download to Scantool".

h. Select "Close" after the download is complete, then select "Back".

i.

Highlight the listed calibration.

j.

Select "Update Controller".

k. When the CCN module update is complete, select "OK".

Computers/Controls - CCN Update For Recall J35|Page 3584 > < Computers/Controls - CCN Update For Recall J35|Page 3582