RAM 3500 HD Truck 2WD L6-6.7L DSL Turbo (2008)
4. The generator shaft uses conventional right-hand threads to attach decoupler. To break decoupler loose from generator threads, rotate end of tool
clockwise.
5. After breaking loose with tool, unthread decoupler by hand from generator.
Installation
INSTALLATION
INA Decoupler
1. Thread decoupler pulley onto generator shaft by hand (right-hand threads).
2. Position Special Tool #8823 (VM.1048) into decoupler.
3. Determine if end of generator shaft is hex shaped or is splined. If hex is used, insert a 10MM deep socket (1) into tool #8823 (VM.1048) or.......