dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 14246 > < Component Tests and General Diagnostics
Page 1
background image

Keyless Entry Transmitter: Programming and Relearning

STANDARD PROCEDURE - RKE TRANSMITTER PROGRAMING

New Remote Keyless Entry (RKE) transmitters can be programed using the scan tool and the proper Diagnostic Procedures manual. The scan tool can
provide confirmation that the PCI data bus is functional, and that all of the electronic modules are sending and receiving the proper messages on the PCI
data bus.

The following procedure can be used as long as one programmed transmitter is available:

NOTE:  When entering program mode using that programmed fob, ALL currently programmed fobs will be erased and they will have to be
reprogrammed for the vehicle. If program mode is entered and no action is performed, the previously programmed fobs will continue to function.

1. Enter the vehicle and close all doors.

2. Fasten the seat belt (this will cancel the seat belt chime). Turn the ignition to the RUN position.

3. Press and hold the UNLOCK button on a programmed transmitter for 4 to 10 seconds. Within the 4 to 10 seconds with the UNLOCK button still

depressed, press the PANIC button for one second. When a single chime is heard, release both buttons.

The chime indicates the system is in program mode.

4. Press and release both the LOCK and UNLOCK buttons simultaneously on a fob to be programmed. A single chime will be heard, this indicates

the fob has been recognized.

5. Press and release any button on the same fob. A single chime will be heard, this indicates the fob has been programmed.

6. Repeat steps 4 and 5 for up to a total of 4 fobs.

7. Turn the ignition OFF.

8. Turn the ignition ON or wait 60 seconds.

The vehicle will remain in program mode for up to 60 seconds from when the original chime (step 3) was heard. After 60 seconds, all
programmed transmitters will function normally.

Component Tests and General Diagnostics|Page 14246 > < Component Tests and General Diagnostics