Accumulator HVAC: Description and Operation
Operation

OPERATION

Refrigerant enters the A/C accumulator (1) mostly as a low pressure vapor through the inlet tube (2). Any liquid, oil-laden refrigerant falls to the bottom
of the canister, which acts as a separator. A desiccant bag (3) is mounted inside the accumulator canister to absorb any moisture which may have entered
and become trapped within the refrigerant system. A filter (4) is also mounted inside the canister to trap any foreign material that may have entered the
refrigerant system during assembly. The low pressure vapor exits the A/C accumulator through the outlet tube (5). On this model, the low side service
port (6) is located at the top of the A/C accumulator.

NOTE:  Replacement of the refrigerant line O-ring seals and gaskets is required anytime a refrigerant line is opened. Failure to replace the rubber O-ring
seals and metal gaskets could result in a refrigerant system leak.

The A/C accumulator has no serviceable parts except for the rubber O-ring seals, low side service port valve, cap and secondary retaining clips. The
O-ring seals used on the connections are made from a special type of rubber not affected by R-134a refrigerant. The O-ring seals must be replaced
whenever the A/C accumulator is removed and installed.

The A/C accumulator cannot be repaired and must be replaced if found to be leaking or damaged, or if an internal failure of the A/C compressor has
occurred.

Accumulator HVAC|Service and Repair > < Accumulator HVAC|Description