Neutral Safety Switch: Testing and Inspection

-

In the START position, the ignition switch connects circuit A1 from the power distribution center (PDC) to circuit A41. A 40 Amp fuse in cavity
15 of the PDC protects circuits A1 and A41.

-

The Park/Neutral position switch and back-up lamp switch are molded together.