side of the distribution duct.

Vacuum Actuator Remove/Install - Typical

4. Using a trim stick or another suitable wide flat-bladed tool, gently pry the actuator latch while pulling firmly upward on the actuator to remove the

actuator from the mount on the distribution duct.

5. Lift the actuator upward until the actuator link is almost parallel with the floor-defrost door lever, then disengage the hole on the end of the link

from the pin on the end of the lever.

6. Remove the floor-defrost door actuator from the distribution duct.
7. Reverse the removal procedures to install.

Floor-panel Door Actuator
1. Disconnect and isolate the battery negative cable.
2. Remove the instrument panel assembly from the vehicle.  Refer to:  "Instrument Panel Gauges and Warning Indicators : Instrument Panel :

Service and Repair"  See: Instrument Panel, Gauges and Warning Indicators/Instrument Cluster / Carrier/Service and Repair

Floor-panel Door Actuator

3. Unplug the two vacuum harness connectors from the floor-panel door actuator located on a mount outboard of the demister outlet on the right side

of the distribution duct.

Blend Door Actuator Replacement|Page 5622 > < Blend Door Actuator Replacement|Page 5620