dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Receiver Dryer > < A/C System - Poor Cooling Performance
Page 1
background image

Hose/Line HVAC: All Technical Service Bulletins
A/C System - Poor Cooling Performance

NO: 24-15-94 Rev. A

GROUP: Heater & A/C

DATE: Nov. 25, 1994

SUBJECT:
Poor A/C Performance

THIS BULLETIN SUPERSEDES TECHNICAL SERVICE BULLETIN 24-15-94 DATED OCT. 7, 1994 WHICH SHOULD BE REMOVED FROM
YOUR FILES. THE REVISION INCREASES THE TIME ALLOWANCE. ALL REVISIONS ARE HIGHLIGHTED WITH **ASTERISKS**.

MODELS:

1994 - 1995

(AA)

Spirit/Acclaim/LeBaron Sedan

1994 - 1995

(AJ)

LeBaron Convertible

1994

(AP)

Shadow/Shadow Convertible/Sundance

SYMPTOM/CONDITION:

Cooling performance of A/C system is poor.

DIAGNOSIS:

Check the refrigerant level and check for R-134a at the discharge and suction line connections of the A/C compressor using the procedures outlined on
Page 24-9 of the 1994 LeBaron, Spirit, Acclaim, Shadow and Sundance Service Manual (Publication No. 81-270-4101). If R-134a is found at the
discharge and/or suction line connections of the A/C compressor, perform the repair procedure.

PARTS REQUIRED:

1

3849730

Gasket, A/C Suction Line to Compressor

1

5264373

Gasket, A/C Discharge Line to Compressor

NOTE:

GASKET PART NUMBERS 4540158 AND 4540157 SHOULD NEVER BE USED ON VEHICLES EQUIPPED WITH R-134a REFRIGERANT
AS DETERIORATION OF THE SEALING CAPABILITIES WILL RESULT AND CAUSE REFRIGERANT TO ESCAPE.

REPAIR PROCEDURE:

This bulletin involves replacing the gaskets between A/C compressor and the discharge and suction lines. Replace both gaskets even if only one
connection is suspect.

1.

Recover any R-134a refrigerant in the A/C system.

2.

Disconnect the A/C discharge and suction lines from the A/C compressor and discard the gaskets.

3.

Install new gaskets, P/N 5264373 on the discharge line and P/N 3849730 on the suction line.

4.

Reconnect the A/C discharge and suction lines to the A/C compressor. Torque the fasteners to 180-220 in. lbs. (20-25 N-m).

5.

Evacuate and recharge the A/C system with R-134a refrigerant using the procedures outlined on Page 24-10 of the 1994 LeBaron, Spirit, Acclaim,
Shadow and Sundance Service Manual (Publication No. 81-270-4101).

POLICY:
Reimbursable within the provisions of the warranty.

TIME ALLOWANCE:
Labor Operation No:

24-45-41-90

**0.8 Hrs.**

FAILURE CODE: P8 - New Part