dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Starting System > < Component Tests and General Diagnostics
Page 2
background image

Fig. 2 Current Output Test.

2. Complete test connections as shown.
3. Remove air hose between engine controller and air cleaner.
4. On non-turbocharged models, connect a suitable jumper wire from green (R3) terminal to ground. Do not connect blue J2 circuit to ground.
5. On turbocharged models, connect a suitable jumper wire from green R3 lead wire on dash side of black 8 way connector to ground. Do not

connect blue J2 lead of 8 way wiring connector to ground.

6. On all models, connect battery ground cable, then start engine and operate at idle.
7. Adjust carbon pile rheostat and engine speed to obtain 15 volts at 1250 RPM. While increasing engine speed, do not allow voltage to exceed 16

volts.

8. If ammeter reading is not within limits shown in "Alternator Specifications, replace alternator.

Starting System > < Component Tests and General Diagnostics