dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Header Seal - Installation Recommendations|Page 3773 > < Header Seal - Installation Recommendations|Page 3771
Page 44
background image

Use a 1/2 or 3/4 inch hose to direct a steady stream of water ten inches from the target areas. The stream should be aimed at right angles to the surface at
all times. Refer to Fig. 24 to identify the following test areas.

AREA A.

30 SECONDS TOTAL

Beginning 1-1/2 in. (38 mm) inboard of the windshield A-pillar, direct a stream of water at the base of the windshield (Fig. 24). Gradually move
rearward in a straight line for 30 seconds (or roughly 25.4 mm [1 in.] per second). Go immediately to B...

AREA B.

60 SECONDS TOTAL

Beginning 1-1/2 in. (38 mm) inboard of the windshield A-pillar, direct a stream of water at the forward edge of the exterior molding. Immediately begin
moving to the opposite side of the exterior molding and onto the top cover material. Continue moving back and forth in this manner for 60 seconds. Go
immediately to C...

AREA C. 30 SECONDS TOTAL

Beginning 1-1/2 in. (38 mm) inboard of the edge of the top cover, direct a stream of water to the front of the top cover. Gradually move rearward in a
straight line for 30 seconds (or roughly 1 1/2 in. [38 mm] per second) to the midpoint above the quarter window.

Verification Inspection Procedure

1.

Inspect for water entry (drips or runs into the vehicle interior) at any point along this path using a flashlight. Mark the entry points with a grease
pencil for reference later. (Mark only on the interior with the grease pencil and make light outline.)

2.

Make the necessary repairs and/or adjustments as required referring back to the appropriate steps in the repair procedure and then repeat the
verification test.

Technical Assistance and Time Allowance

Technical Assistance

If a dealer needs technical assistance with the installation of this package, a Diagnostic Worksheet can be found at the back of this bulletin that can be
photocopied and filled out. After the Diagnostic Worksheet has been filled out, contact your zone by phone to get technical assistance.

POLICY:
Reimbursable within the provisions of the warranty.

TIME ALLOWANCE:
Labor Operation No. 23-51-35-91 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.8 Hrs.

FAILURE CODE:
4X - Water Leak

Header Seal - Installation Recommendations|Page 3773 > < Header Seal - Installation Recommendations|Page 3771