dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Heater Outlets - Emit Moisture/Condensation|Page 3064 > < Blower Motor|Flow of Diagnosis|Page 3055
Page 1
background image

Blower Motor Resistor: Customer Interest
Heater Outlets - Emit Moisture/Condensation

NO.: 24-06-93
GROUP: Air Conditioning
EFFECTIVE DATE: Mar. 12, 1993

SUBJECT:
Moisture Coming Out Of The Heater Outlets

MODELS:

1991-1993 (AA)

Acclaim/Spirit/LeBaron Sedan

(AP)

Sundance/Shadow/Shadow Convertible

SYMPTOM/CONDITION:

Some vehicles may exhibit moisture/condensate exiting the heater outlets when operating the A/C system in high ambients and/or high humidity with the
blower switch on high and air flow in the bi-level mode for extended periods of time.

PARTS REQUIRED:

1

Resistor Block

4462841

2

Heat Shrink Sleeve

4419644

2

Tie Strap

6015756

1

Wire Overlay

4741933

REPAIR PROCEDURE:

This bulletin involves replacing the resistor block and installation of a wire overlay harness from the resistor block to the blower motor circuit.

1.

Disconnect the battery.

2.

Remove the glove box, as outlined in the appropriate service manual, to gain access to the blower motor and resistor block wiring harnesses. Also
remove any relay mounting brackets attached to the upper glove box opening. Locate the blower motor wiring harness black 2-way connector and
carefully remove it from its mounting surface. Disconnect the connector.

3.

In the engine compartment, remove the existing blower motor resistor block, as outlined in the appropriate service manual, and replace it with
resistor block P/N 4462841, see Figure 1.

Heater Outlets - Emit Moisture/Condensation|Page 3064 > < Blower Motor|Flow of Diagnosis|Page 3055