dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Air Leak At A/C Unit|Page 4780 > < Air Leak At A/C Unit
Page 2
background image

FIGURE 1

REPAIR PROCEDURE (Figure 1)

1.

Remove glove box. Note the location and width of the gap between plenum floor and the A/C unit seal.

2.

Remove the seven screws and the recirculating air housing assembly.

NOTE:

IN ORDER TO REMOVE ONE OF THE LOWER RIGHT HAND SCREWS, IT WILL FIRST BE NECESSARY TO REMOVE THE
RIGHT SIDE COWL TRIM PAD, AND THE TWO SCREWS FROM THE RECIRCULATING DOOR ACTUATOR, AND MOVE IT
TO THE RIGHT AS FAR AS POSSIBLE.

3.

Attach seal material to the under side of the plenum floor in the area of the gap (unit cover can be deflected downward to aid installation of the
seal). Several layers of seal material may be used if necessary.

4.

Install recirculating air housing, remount actuator, and install right side cowl trim panel.

5.

Install glove box.

Air Leak At A/C Unit|Page 4780 > < Air Leak At A/C Unit