57.

Install the PCV tube.

58.

Install the air cleaner. Install the air cleaner hose clamp with the screw on the top of the hose, so that it does not interfere with the heat shield,
(Figure 19). Tighten the clamp to 30 in.lbs. (4 N-m) torque.

NOTE:
When installing the air cleaner, ensure that the oxygen sensor wiring is routed and clipped between the heat shield and the air cleaner, above the heat
shield. Check that the oxygen sensor wiring connector is oriented properly (Figure 20) and clipped to the heat shield to prevent the harness from
contacting the turbocharger housing or exhaust manifold. Use the supplied clips to secure the wiring and the wiring connector in the event that either is
broken.