Sprinter 2500 L5-2.7L DSL Turbo (2003)
The regulating valve pressure (p-RV) is set at the regulating valve pressure regulating valve (1) (Fig. 108) in relation to the working pressure (p-A) as
far as the maximum pressure.
Shift Valve Pressure Regulating Valve
The non-constant regulating valve pressure (p-RV) is regulated to a constant shift valve pressure (p-SV) at the shift valve pressure regulating valve (1)
(Fig. 109) and is used to supply the 1-2 and 4-5 / 3-4 / 2-3 solenoid valves and the torque converter lockup clutch PWM solenoid valve.