Sprinter 2500 V6-3.0L DSL Turbo VIN 45 (2007)
Ignition Switch: Service and Repair
Installation
INSTALLATION
1. Reconnect the EIS harness connector and install the EIS (3).
2. Position the EIS (3) in the instrument panel.
NOTE: The guide of the shift-lock cable on the EIS control unit (arrow) should point downward.
NOTE: Two shims may be present. If present, ensure that the smaller shim is installed between the EIS bezel and the outer surface of the
instrument panel. The larger shim (2) is installed between the EIS assembly (3) and the inner surface of the instrument panel.
3. Use the EIS bezel wrench 10086 to tighten the EIS bezel (1). Tighten the EIS bezel to 7 Nm (5 lb. ft).
4. Reconnect the EIS harness connector.
5. Install the left floor duct screw (3).