Alternator Pulley: Description and Operation

Generator Decoupler Pulley

The generator decoupler is used only with certain engines. The decoupler is used in place of the standard generator drive pulley. 

The generator decoupler is used only with certain engines. The decoupler is a one-way clutch designed to help reduce belt tension fluctuation, vibration,
reduce fatigue loads, improve belt life, reduce the loads on components, and reduce noise. Dry operation is used (no grease or lubricants). The decoupler
is not temperature sensitive and also has a low sensitivity to electrical load. The decoupler is a non-serviceable item and is to be replaced as an assembly.