Sprinter 3500 L5-2.7L DSL Turbo (2004)
Seals and Gaskets: Service and Repair
Torque Converter Hub Seal
TORQUE CONVERTER HUB SEAL
REMOVAL
1. Remove the torque converter.
2. Remove the torque converter hub seal with suitable screw and slide hammer.
INSTALLATION
1. Position the torque converter hub seal (1) (Fig. 249) over the input shaft and against the transmission oil pump.
2. Using Seal Installer 8902A (2) (Fig. 250), install a new torque converter hub seal.
3. Install the torque converter.