Expansion Valve: Testing and Inspection
Plumbing - Front

FRONT A/C EXPANSION VALVE

WARNING:  Review safety precautions and warnings before performing this procedure. Failure to follow the warnings and cautions may
result in serious or fatal injury.

NOTE:  The A/C expansion valve should only be tested following testing of the A/C compressor.

NOTE:  Liquid CO2 is required to test the A/C expansion valve. This material is available from most welding supply facilities. Liquid CO2 is also
available from companies which service and sell fire extinguishers.

When testing the A/C expansion valve, the work area and the vehicle temperature must be 21° to 27° C (70° to 85° F). To test the expansion valve:

1. Connect a charging station or manifold gauge set to the refrigerant system service ports. Verify the refrigerant charge level.
2. Close all doors, windows and vents to the passenger compartment.
3. Set the A/C-heater temperature control to the highest temperature position, adjust the mode control to direct air output to the floor and set the 

blower motor to its highest operating speed.

4. Start the engine and allow it to idle. Allow the passenger compartment to heat up and the engine to reach normal operating temperatures. This will

create the need for maximum refrigerant flow into the A/C evaporator.

5. If the refrigerant charge is sufficient, the discharge (high pressure) gauge should read 827 kPa to 1655 kPa (120 psi to 240 psi). The suction (low

pressure) gauge should read 207 kPa to 345 kPa (30 psi to 50 psi). If OK, go to STEP 6. If not OK, replace the faulty A/C expansion valve.

WARNING:  Protect the skin and eyes from exposure to liquid CO2 or personal injury can result.

6. If the suction (low pressure) gauge reads within the specified range, freeze the A/C expansion valve for 30 seconds using liquid CO2 or another

suitable super-cold material. Do not spray R-134a or R-12 refrigerant on the A/C expansion valve for this test. The suction (low pressure)
gauge reading should drop by 69 kPa (10 psi). If OK, go to STEP 7 If not OK, replace the faulty A/C expansion valve.

7. Allow the expansion valve control head to thaw. The suction (low pressure) gauge reading should stabilize at 207 kPa to 345 kPa (30 psi to 50

psi). If not OK, replace the faulty A/C expansion valve.

8. When expansion valve testing is complete, test the overall A/C system performance.

Plumbing - Front|Page 5612 > < Plumbing - Front|Page 5609