Page 1
background image

Refrigerant: Tools and Equipment

REFRIGERANT SYSTEM SERVICE EQUIPMENT

WARNING:  Eye protection must be worn when servicing an A/C refrigerant system. Turn all valves off (rotate clockwise) on the equipment
being used before connecting or disconnecting service equipment from the refrigerant system. Failure to observe these warnings may result in
serious or fatal injury.

WARNING:  Review safety precautions and warnings before performing this procedure. Failure to follow the warnings and cautions may
result in serious or fatal injury.

When servicing the front or optional rear A/C system, a R-134a refrigerant recovery/recycling/charging station that meets SAE standard J2210 must be
used (1). Contact an automotive service equipment supplier for refrigerant recovery/recycling/charging equipment. Refer to the operating instructions
supplied by the equipment manufacturer for proper care and use of this equipment.

A manifold gauge set (1) may be needed with some recovery/recycling/charging equipment. The manifold gauge set should have manual shut-off valves
(2 and 6), or automatic back-flow valves located at the service port connector end of the manifold gauge set hoses (4 and 5). This will prevent refrigerant
from being released into the atmosphere.

REFRIGERANT PORT CONNECTIONS-FRONT A/C SYSTEM

CAUTION:  Do not use an R-12 manifold gauge set on an R-134a system. The refrigerants are not compatible and system damage will result.

RECOVERY/RECYCLING/EVACUATION/CHARGING HOSE The center manifold hose (Yellow, or White, with Black stripe) (3) is used to

Refrigerant System Recovery|Page 5686 > < Refrigerant System Recovery|Page 5684