dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Control Module HVAC > < Controls - Front
Page 1
background image

Condenser Fan Motor Relay: Service and Repair
Controls - Rear

Removal

REMOVAL

1. Disconnect and isolate the negative battery cable.
2. Remove the screws that secure the rear condenser cover to the top of the vehicle and remove the cover.
3. Remove the screw (1) that secures the rear condenser fan relay (2) to left side of the rear condenser mounting bracket (4).
4. Remove the rear condenser fan relay from the mounting bracket and disconnect the wire harness connector (3) from the relay.

Installation

INSTALLATION

1. Position the rear condenser fan relay (2) to left side of the rear condenser mounting bracket (4) located on top of the vehicle.
2. Align the rear condenser fan relay with the terminal cavities in the wire connector (3) and engage the connector onto the relay. Make sure the

terminals and wire connector are fully seated.

3. Install the screw (1) that secure the rear condenser fan relay to the rear condenser mounting bracket. Tighten the screw securely.
4. Install the rear condenser cover and the retaining screws. Tighten the screws to 2 Nm (17 in. lbs.).
5. Reconnect the negative battery cable.

Control Module HVAC > < Controls - Front