dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Catalytic Converter|Locations|Page 1573 > < Catalytic Converter|Locations
Page 1
background image

Catalytic Converter: Service and Repair

CATALYTIC CONVERTER 

REMOVAL 

WARNING:  THE NORMAL OPERATING TEMPERATURE OF THE EXHAUST SYSTEM IS VERY HIGH. THEREFORE, NEVER
ATTEMPT TO SERVICE ANY PART OF THE EXHAUST SYSTEM UNTIL IT IS COOLED. SPECIAL CARE SHOULD BE TAKEN
WHEN WORKING NEAR THE CATALYTIC CONVERTER. THE TEMPERATURE OF THE CONVERTER RISES TO A HIGH
LEVEL AFTER A SHORT PERIOD OF ENGINE OPERATION TIME.
 

1. Remove muffler and exhaust pipe.
2. Disconnect the downstream oxygen sensor electrical connector. 

3. Remove the exhaust manifold support bracket (LEV only) (Fig. 7).

4. Remove catalytic converter to exhaust manifold attaching fasteners and remove converter from vehicle (Fig. 8).
5. Remove and discard the flange gasket.

NOTE:  When replacement is required on any component of the exhaust system, original equipment parts (or equivalent) must be used.

INSPECTION 

WARNING:  THE NORMAL OPERATING TEMPERATURE OF THE EXHAUST SYSTEM IS VERY HIGH. THEREFORE, NEVER
ATTEMPT TO SERVICE ANY PART OF THE EXHAUST SYSTEM UNTIL IT IS COOLED. SPECIAL CARE SHOULD BE TAKEN
WHEN WORKING NEAR THE CATALYTIC CONVERTER. THE TEMPERATURE OF THE CONVERTER RISES TO A HIGH
LEVEL AFTER A SHORT PERIOD OF ENGINE OPERATION TIME.
 

Check catalytic converter for a flow restriction. (Refer to - EXHAUST SYSTEM - DIAGNOSIS AND TESTING) Exhaust System Restriction Check

Catalytic Converter|Locations|Page 1573 > < Catalytic Converter|Locations